Chapter 17 Special Inspections and Tests
California amendments by OSHPD
Office of Statewide Health Planning and Development
1705.3.9 (formerly 1705.19) Shotcrete and 1705.3.9.1 (formerly 1705.19.1) Visual examination for structural soundness of in-place shotcrete
Existing amendments about shotcrete inspections and tests relocated to Section 1705.3 that addresses concrete construction.
1705.3.9.2 Preconstruction tests
ICC deleted requirements for shotcrete from the model code Section 1908 as they are now incorporated in referenced standard ACI 318-19, so OSHPD added new section 1705.3.9.1 to incorporate requirements previously located in an amendment to Section 1908A.10.2 and model code Sections 1908.4.1 and 1908.5.